HP Converged Network Utility
=============================
Version:      2.0.11-1
Release Date: DEC 19, 2014

1. Bug Fixes
============
[Linux]
a) QXCR1001385113 - CNU SLES12 Breezy, can't boot into OS when HP-CNU installed.
b) QXCR1001384442 - DL380p Gen8_SLES 12 OS enters to emergency mode on installing CNU pre-requisites
c) QXCR1001384359 - iSCSI info is not getting listed under HP-CNU for Barracuda in SLES12 OS
d) QXCR1001380544 - CNU-Linux fails to upgrade from version to version (1.x to 2.x or 2.x to 2.y)
e) Using the showadapter command will cause the CNUCLI core dump. (root cause: external link of model.h was wrong.)

[Windows]
a) Using the showadapter command will cause the CNUCLI core dump. (root cause: external link of model.h was wrong.)

2. Available features/functionality
===================================
a) CNA discovery
b) iSCSI Port, Initiator discovery
c) iSCSI Target Portal, Target configurationc
d) iSNS configuration
e) iSCSI Target,LUN discovery
f) iSCSI Target Session & iSCSI Port Statistics discovery
g) FCoE Port discovery
h) FCoE Port Statistics 
i) Configured FCoE Target mappings discovery
j) Configured FCoE Target & LUN discovery
k) Configured FCoE Persistent Bindings discovery
l) Configured DCB discovery for FCoE
m) FCoE get and set operations for DCB.
n) FCoE get and set operations for Boot Configuration.
o) iSCSI get and set operations for Boot Configuration.
p) Ping Functionality for iSCSI.
q) Ping Functionality for FCoE.

Note: Feature 'Get the actual link speed of iSCSI port' follows Common Information Model (CIM) on both Windows and Linux systems.


3. Limitations/Known issues
===========================
a) Localization pending for some newly introduced features.
b) Help page is not context sensitive.
c) GUI iconography is not final and will be improved in subsequent releases.
d) Dashborad screen (landing page) is not final and will be changed in subsequent releases.
e) On Linux, there may be intermittent issues seen w.r.t iSCSI boot or FCoE boot configuration as well as DCB configurtion. Follow these steps as workaround:
	- Execute this command from /usr/lib64/Pegasus/providers: 			execstack -c *.so
	- Stop cimserver by executing this: cimserver -s
	- Start cimserver by executing this: cimserver
f) iSCSI ping test feature is not available on Linux due to open-iscsi limitation.
g) iSCSI statistics feature is not available on Linux due to open-iscsi limitation.
h) iSCSI Immediate data is not configuable on Windows due to Broadcom limitation.
i) iSNS support on Linux will be added in a future release.
j) HPSUM's remote deplyment function doesn't work properly for CNU.
k) Linux doesn't support FCoE Statistic yet.
l) On Linux, if there is an error show up after starting tog-pegasus CIM Server like below
   "cimserver not started: SSL Exception: Could not access server certificate in /etc/Pegasus/server.pem."
	- start cimserver by executing this: service tog-pegasus start 
m) On Linux, if there is no adapter show in CNU : 
     1. Close the CNU
     2. Restart the cimserver by :
        - cimserver -s
        - cimserver
n) On Linux, if iSCSI IPv4/IPv6 address configuration cannot be modified, please check if there is any logged-in target. If so, please log out all target before modify IPv4/IPv6 address.
o) About Linux upgrading, for previous releases of CNU (NCDE 11.00 and before), users will need to manually uninstall the old RPM on both RHEL and SLES.

4. System Component Update
==========================
a) Update the library of Braodcom CIMProvider from v2.5.22 to v2.5.24 (since CNU V 2.0.9-1)
      - /CNA/branch/ncde1110/Build/Prerequisite/Broadcom/CMPI_Linux/BRCM_CMPIProvider-2.5.22-0.i386.rpm -> BRCM_CMPIProvider-2.5.24-0.i386.rpm
      - /CNA/branch/ncde1110/Build/Prerequisite/Broadcom/CMPI_Linux/BRCM_CMPIProvider-2.5.22-0.x86_64.rpm -> BRCM_CMPIProvider-2.5.24-0.x86_64.rpm