Copyright(c) 2013 - 2018 Intel Corporation

This release includes the native i40en VMware ESX Driver for Intel(R) Ethernet Controllers X710, XL710, XXV710, and X722 family

Driver version: 1.7.11

Supported ESXi release: 6.7

=================================================================================

Contents
--------

- Important Notes
- Supported Features
- New Features
- New Hardware Supported
- Physical Hardware Configuration Maximums
- Bug Fixes
- Known Issues and Workarounds
- Command Line Parameters
- Previously Released Versions

=================================================================================

Important Notes:
----------------

- Recovery Mode
	A device will enter recovery mode if a device's NVM becomes corrupted.
	If a device enters recovery mode because of an interrupted NVM update, you should attempt to finish the update.
	If the device is in recovery mode because of a corrupted NVM, use the nvmupdate utility to reset
	the NVM back to factory defaults.

	NOTE: You must power cycle your system after using Recovery Mode to completely reset the firmware and hardware.

- Backplane devices
	Backplane devices are operating in auto mode only, and thus the user cannot manually overwrite speed settings.

- VLAN Tag Stripping Control for VF drivers
	VLAN Tag Stripping Control feature is enabled by default but can be disabled by VF driver.
	On a Linux VM with i40evf SR-IOV device (VF) driver, use below command to control the feature:
	ethtool --offload <IF> rxvlan on/off

	NOTE: Disabling VLAN Tag Stripping is only applicable to Virtual Guest Tagging (VGT) configurations.
	NOTE: VLAN Tag Stripping Control feature is currently not available on Windows VF drivers.

- Malicious Driver Detection (MDD)
	Malicious Driver Detection feature protects NIC from malformed packets or any other hostile actions
	which may be performed by drivers operating with the NIC (accidentally or deliberately)
	In case of detecting Malicious Driver event, driver reacts in below ways:
	  - if the source of the MDD event was i40en driver (Physical Function [PF] driver), hardware is reset;
	  - if the source of the MDD event was Virtual Machine's SR-IOV driver (Virtual Function [VF] driver),
	    suspected VF is disabled after 4th such event - malicious VM SR-IOV adapter becomes unavailable.
	    To bring it back, VM reboot or VF driver reload is required.

- LLDP Agent
	Link Layer Discovery Protocol (LLDP) supports Intel X710 and XL710 adapters with FW 6.0 and later
	as well as X722 adapters with FW 3.10 and later.
	Set LLDP driver load param to allow or disallow LLDP frames forwarded to the network stack

	  LLDP agent is enabled in firmware by default (Default FW setting)
	  Set LLDP=0 to disable LLDP agent in firmware
	  Set LLDP=1 to enable LLDP agent in firmware
	  Set LLDP to anything other then 0 or 1 will fallback to the default setting (LLDP enabled in firmware)
	  LLDP agent is always enabled in firmware when MFP (Multi Functional Port, i.e. NPAR) is enabled,
	  regardless of the driver parameter LLDP setting.

	When the LLDP agent is enabled in firmware, the ESXi OS will not receive LLDP frames and Link Layer
	Discovery Protocol information will not be available on the physical adapter inside ESXi.

	Please note that the LLDP driver module parameter is an array of values. Each value represents LLDP agent
	setting for a physical port.
	Please refer to "Command Line Parameters" section for suggestions on how to set driver module parameters.


Supported Features:
-------------------

- Rx, Tx, TSO checksum offload
- Netqueue (VMDQ)
- VxLAN Offload
- Geneve Offload
- Hardware VLAN filtering
- Rx Hardware VLAN stripping
- Tx Hardware VLAN inserting
- Interrupt moderation
- SR-IOV (supports four queues per VF, VF MTU, and VF VLAN)
        Valid range for max_vfs
        1-32 (4 port devices)
        1-64 (2 port devices)
        1-128 (1 port devices)
- Link Auto-negotiation
- Flow Control
- Management APIs for CIM Provider, OCSD/OCBB
- Firmware Recovery Mode


New Features:
-------------

- Implemented VLAN Tag Stripping Control for VF drivers
- Implemented LLDP Agent control for X722 adapters (supported in FW 3.10 and later)


New Hardware Supported:
-----------------------

- None


Physical Hardware Configuration Maximums:
--------------------------------
40Gb Ethernet Ports (Intel) = 4
25Gb Ethernet Ports (Intel) = 4
10Gb Ethernet Ports (Intel) = 16


Bug Fixes:
----------

- Fixed Malicious Driver Detection (MDD) event handling. Previous drivers detected MDD events but did not properly reset
  the adapter. The PF driver also now properly disables an offending VF after it detects 4 MDD events on the same VF.
- Fixed an issue where SR-IOV was unable to be enabled via Web Client when i40en driver failed to load all PFs.
- Fixed a PSOD when booting a Supermicro X710DAi with X722 adapters.
- Fixed link not being detected while toggling Promiscuous Mode on a VF interface which could lead to VM instability and spontaneous rebooting.


Known Issues and Workarounds:
----------------------------

- Very low throughput when sending IPv6 to a Linux VM that uses a VMXNET3 adapter
	Workaround: Please look at the VMware Knowledge Base 2057874
- Driver is unable to configure the maximum 128 Virtual Functions per adapter due to the kernel limitation
	Workaround: Please look at the VMware Knowledge Base 2147604
- Cannot set maximum values for VMDQ and SR-IOV VFs on a port at the same time
	Workaround: Reduce the VMDQ or max_vfs value for the port
- In MFP adapter mode multicast traffic does not work on emulated adapters when a VM with an SR-IOV VF adapter is powered on
	Workaround: Do not mix SR-IOV and emulated traffic in MFP mode
- Setting Geneve options length larger than 124 bytes causes VLAN-tagged Geneve traffic to drop
	Workaround: Don't set Geneve options length to more than 124 bytes or don't assign a VLAN to Geneve tunnel
- In RHEL 7.2 an IPv6 connection persists between VF adapters after changing port group VLAN mode from trunk (VGT) to port VLAN (VST)
	Workaround: Upgrade to RHEL 7.3 or newer. This is a Linux kernel bug that causes packets to arrive at the wrong virtual interface.
- Disabling VFs due to MDD events caused by configuring VF adapters as 'PCI Device' instead of 'SR-IOV Passthru Device'
	Workaround: Configure VMs with 'SR-IOV Passthru Device'
- Switching port (vmnic) of management uplink may lead to connectivity issues
	Workaround: Switch the port of management uplink back to the original one


Command Line Parameters:
------------------------

ethtool is not supported for native driver.
Please use esxcli, vsish, or esxcfg-* to set or get the driver information, for example:

- Get the driver supported module parameters
  esxcli system module parameters list -m i40en

- Set a driver module parameter (clearing other parameter settings)
  esxcli system module parameters set -m i40en -p LLDP=0

- Set a driver module parameter (other parameter settings left unchanged)
  esxcli system module parameters set -m i40en -a -p LLDP=0

- Get the driver info
  esxcli network nic get -n vmnic1

- Get an uplink stats
  esxcli network nic stats -n vmnic1

- Get the private stats
  vsish -e get /net/pNics/vmnic1/stats


=================================================================================

Previously Released Versions:
-----------------------------
- Driver Version: 1.7.5
	Hardware Supported: Intel(R) Ethernet Controllers X710, XL710, XXV710, and X722 family
	Supported ESXi releases: 6.0, 6.5 and 6.7
	New Features Supported:
		- Introduced support for firmware recovery mode
	Bug Fixes:
		- None
	Known Issues:
		- Very low throughput when sending IPv6 to a Linux VM that uses a VMXNET3 adapter
			Workaround: Please look at the VMware Knowledge Base 2057874
		- Driver is unable to configure the maximum 128 Virtual Functions per adapter due to the kernel limitation
			Workaround: Please look at the VMware Knowledge Base 2147604
		- Cannot set maximum values for VMDQ and SR-IOV VFs on a port at the same time
			Workaround: Reduce the VMDQ or max_vfs value for the port
		- In MFP adapter mode multicast traffic does not work on emulated adapters when a VM with an SR-IOV VF adapter is powered on
			Workaround: Do not mix SR-IOV and emulated traffic in MFP mode
		- Setting Geneve options length larger than 124 bytes causes VLAN-tagged Geneve traffic to drop
			Workaround: Don't set Geneve options length to more than 124 bytes or don't assign a VLAN to Geneve tunnel
		- In RHEL 7.2 an IPv6 connection persists between VF adapters after changing port group VLAN mode from trunk (VGT) to port VLAN (VST)
			Workaround: Upgrade to RHEL 7.3 or newer. This is a Linux kernel bug that causes packets to arrive at the wrong virtual interface.
		- X722 adapter causes PSOD on Supermicro X10DAi
			Workaround: None


- Driver Version: 1.7.1
	Hardware Supported: Intel(R) Ethernet Controllers X710, XL710, XXV710, and X722 family
	Supported ESXi releases: 6.7
	New Features Supported:
		- New i40en driver for ESXi 6.7 based on the ESX 6.0/6.5 i40en v1.5.8 driver with additional bug fixes
	Bug Fixes:
		- Reduced driver's memory footprint
		- Prevent VxLAN port reprogramming failures after changing VxLAN port more than 16 times
		- Prevent dropped packets during link speed change
		- Don't show a link down message on SFP+ module removal
		- Fix for dropped emulated adapter traffic between MFP mode master and slave partitions
		- Fix for the NIC down procedure hanging when heavy traffic is running.
		- Fixed intermittent link flap after running NVM Update
		- Fixed multicast traffic not being received on emulated adapters when a VM with an SR-IOV VF adapter is powered on
		- Fix for SR-IOV VF adapters hanging when PF is brought down
		- Fixed issue with enabling 128 VF's on single port adapters
		- Show correct cable types for AUI, MII and 1000BaseT-Optical link types
		- Fix intermittent PSOD during NVM Update
		- Fix for MDD event and TX hang caused by TSO_MSS option smaller than 64 bytes
		- Fixed issue where adapter could end up in a reset loop after a TX hang event
		- Show an error message when trying to set invalid pause frame parameters
		- Fix for 'Failed to add Geneve cloud filter' message when running heavy Geneve traffic
		- Fix for VF driver hang when GOS requested VF promiscuous mode
		- Fix for intermittent packet loss when link is brought down and up
	Known Issues:
		- Very low throughput when sending IPv6 to a Linux VM that uses a VMXNET3 adapter
			Workaround: Please look at the VMware Knowledge Base 2057874
		- Driver is unable to configure the maximum 128 Virtual Functions per adapter due to the kernel limitation
			Workaround: Please look at the VMware Knowledge Base 2147604
		- Cannot set maximum values for VMDQ and SR-IOV VFs on a port at the same time
			Workaround: Reduce the VMDQ or max_vfs value for the port
		- In MFP adapter mode multicast traffic does not work on emulated adapters when a VM with an SR-IOV VF adapter is powered on
			Workaround: Do not mix SR-IOV and emulated traffic in MFP mode
		- Setting Geneve options length larger than 124 bytes causes VLAN-tagged Geneve traffic to drop
			Workaround: Don't set Geneve options length to more than 124 bytes or don't assign a VLAN to Geneve tunnel
		- In RHEL 7.2 an IPv6 connection persists between VF adapters after changing port group VLAN mode from trunk (VGT) to port VLAN (VST)
			Workaround: Upgrade to RHEL 7.3 or newer. This is a Linux kernel bug that causes packets to arrive at the wrong virtual interface.
		- X722 adapter causes PSOD on Supermicro X10DAi
			Workaround: None