Configuration : Creating a New Storage Configuration Using The Simple Configuration Option

Creating a New Storage Configuration Using The Simple Configuration Option

Simple configuration is the quickest and easiest way to create a new storage configuration. When you select simple configuration mode, the system creates the best configuration possible using the available drives.

Perform the following steps to create a simple storage configuration:

1.

On the Server dashboard or on the Controller dashboard, select Configure > Simple Configuration.

The Simple Configuration page opens.

2.

From the available RAID level, select a RAID level for the array from the drop-down box.

3.

(Optional) click Compare and Select to view the detailed information on each RAID level.

When you use simple configuration, the RAID controller supports RAID levels 0, 1, 5, 6, and10. The window text gives a brief description of the RAID level that you select. The RAID levels that you can choose depend on the number of drives available.

4.

Select the number of logical drives you want to create.

5.

Select the capacity of the logical drives. Each logical drive has the same capacity.

6.

Select the Assign Spare check box if you want to assign a dedicated spare drive to the new logical drive.

If an unconfigured good drive is available, that drive is assigned as a spare drive spare drive. Spare drives are drives that are available to replace failed drives automatically in a redundant logical drive (RAID 1, RAID 5, RAID 6, or RAID 10).

7.

Click Finish.

A message appears stating that the configuration is successfully created.