            2.  Abstract
            
            This memo defines a private portion of the Management 
            Information Base (MIB), within the Xyplex branch, for use 
















            
            
                                                               [Page   1]


            
                           XYPLEX IEEE ETHERNET HUB MIB      18 Oct 91
            
            
            
            with SNMP over various transport services, such as UDP or 
            Ethernet.  In particular, it defines objects in the IEEE 
            802.3 Hub Management model [11] for managing a Xyplex 
            Ethernet hub.
            
            This memo does not specify a standard for the Internet 
            community.  It describes a standard for Xyplex products.







































            
            
                                                               [Page   2]


            
                           XYPLEX IEEE ETHERNET HUB MIB      18 Oct 91
            
            
            
            3.  Historical Perspective
            
            As reported in RFC 1052, IAB Recommendations for the 
            Development of Internet Network Management Standards [1], a 
            two-prong strategy for network management of TCP/IP-based 
            internets was undertaken.  In the short-term, the Simple 
            Network Management Protocol (SNMP), defined in RFC 1067, was 
            to be used to manage nodes in the Internet community.  In 
            the long-term, the use of the OSI network management 
            framework was to be examined.  Two documents were produced 
            to define the management information: RFC 1065, which 
            defined the Structure of Management Information (SMI), and 
            RFC 1066, which defined the Management Information Base 
            (MIB).  Both of these documents were designed so as to be 
            compatible with both the SNMP and the OSI network management 
            framework.
            
            This strategy was quite successful in the short-term: 
            Internet-based network management technology was fielded, by 
            both the research and commercial communities, within a few 
            months.  As a result of this, portions of the Internet 
            community became network manageable in a timely fashion.
            
            As reported in RFC 1109, Report of the Second Ad Hoc Network 
            Management Review Group [2], the requirements of the SNMP 
            and the OSI network management frameworks were more 
            different than anticipated.  As such, the requirement for 
            compatibility between the SMI/MIB and both frameworks was 
            suspended.  This action permitted the operational network 
            management framework, based on the SNMP, to respond to new 
            operational needs in the Internet community by producing 
            MIB-II.
            
            In May of 1990, the core documents were elevated to 
            "Standard Protocols" with "Recommended" status.  As such, 
            the Internet- standard network management framework consists 
            of: Structure and Identification of Management Information 
            for TCP/IP-based internets, RFC 1155 [4], which describes 
            how managed objects contained in the MIB are defined; 
            Management Information Base for Network Management of 
            TCP/IP-based internets, which describes the managed objects 
            contained in the MIB, RFC 1156 [5]; and, the Simple Network 
            Management Protocol, RFC 1157 [6], which defines the 
            protocol used to manage these objects.
            
            Consistent with the IAB directive to produce simple, 

            
            
                                                               [Page   3]


            
                           XYPLEX IEEE ETHERNET HUB MIB      18 Oct 91
            
            
            
            workable systems in the short-term, the list of managed 
            objects defined in the Internet-standard MIB was derived by 
            taking only those elements which are considered essential.  
            However, the SMI defined three extensibility mechanisms: 
            one, the addition of new standard objects through the 
            definitions of new versions of the MIB; two, the addition of 
            widely-available but non- standard objects through the 
            experimental subtree; and three, the addition of private 
            objects through the enterprises subtree.  Such additional 
            objects can not only be used for vendor-specific elements, 
            but also for experimentation as required to further the 
            knowledge of which other objects are essential.
            
            This memo defines extensions to the MIB using the third 
            method.  It contains definitions of managed objects in 
            various Xyplex products, using ASN.1 conventions specified 
            in [10].





























            
            
                                                               [Page   4]


            
                           XYPLEX IEEE ETHERNET HUB MIB      18 Oct 91
            
            
            
            4.  Objects
            
            Managed objects are accessed via a virtual information 
            store, termed the Management Information Base or MIB.  
            Objects in the MIB are defined using the subset of Abstract 
            Syntax Notation One (ASN.1) [7] defined in the SMI.  In 
            particular, each object has a name, a syntax, and an 
            encoding.  The name is an object identifier, an 
            administratively assigned name, which specifies an object 
            type.  The object type together with an object instance 
            serves to uniquely identify a specific instantiation of the 
            object.  For human convenience, we often use a textual 
            string, termed the OBJECT DESCRIPTOR, to also refer to the 
            object type.
            
            The syntax of an object type defines the abstract data 
            structure corresponding to that object type.  The ASN.1 
            language is used for this purpose.  However, the SMI [4] 
            purposely restricts the ASN.1 constructs which may be used. 
            These restrictions are explicitly made for simplicity.
            
            The encoding of an object type is simply how that object 
            type is represented using the object type's syntax.  
            Implicitly tied to the notion of an object type's syntax and 
            encoding is how the object type is represented when being 
            transmitted on the network.
            
            The SMI specifies the use of the basic encoding rules of 
            ASN.1 [8], subject to the additional requirements imposed by 
            the SNMP.
            
            
            4.1.  Format of Definitions
            
            Section 6 contains the specification of all object types 
            contained in this MIB module.  The object types are defined 
            using the conventions defined in the SMI, as amended by the 
            extensions specified in [9].








            
            
                                                               [Page   5]


            
                           XYPLEX IEEE ETHERNET HUB MIB      18 Oct 91
            
            
            
            5.  Overview
            
            IEEE 802 defines management parameters for Ethernet hubs in 
            [11].  That document is a draft, expected to change, but 
            provides useful guidance in defining a hub MIB.  The Xyplex 
            IEEE 802 Hub MIB is based heavily on that document, but does 
            not implement it exactly.  In particular, IEEE 802 defines 
            the MIB to contain multiple hubs that can contain multiple 
            groups of hub ports.  Xyplex hubs do not support that model, 
            reducing it to a single, scalar instance of hub and group.
            
            The Xyplex IEEE 802 Hub MIB applies to Xyplex systems that 
            act as an Ethernet hub.
            
            The IEEE 802 Hub MIB is mandatory for all Xyplex hubs 
            managed via SNMP.
            
            The MIB comprises functional groups, and each group may in 
            turn contain base objects and tables.
            
            As a convenience to the reader, the groups are:
            
                hmBasicCapability
                hmSelfTestCapability
                hmPerfMonCapability
                hmAddrTrackCapability
                hmBadBitClockCapability
            
            The IEEE MIB contains an additional, optional group, 
            hmGuageCapability, that the Xyplex MIB does not include.
            
            The basic group contains base objects and a port table.  The 
            basic group base objects are:
            
                hubBasicID
                hubGroupCapacity
                hubGroupMap
            
                groupHubBasicID
                groupBasicID
                groupNumberOfPorts
            
            The basic group port table contains:
            
                portHubBasicID
                portGroupBasicId

            
            
                                                               [Page   6]


            
                           XYPLEX IEEE ETHERNET HUB MIB      18 Oct 91
            
            
            
                portBasicId
                portType
                portAdminState
                portAutoPartitionState
            
            The self test group contains:
            
                hubSelfTestID
                hubResetTimeStamp
                hubHealthState
                hubHealthText
                hubHealthData
                hubSystemResetting
                hubResetting
                hubExecutingSelfTest
            
            The performance monitor group contains base objects and a 
            port table.  The base objects are:
            
                relayHubPerfID
                relayPerfID
                relayTotalCollisions
            
            The performance monitor group port table contains:
            
                portHubPerfID
                portGroupPerfID
                portPerfID
                portReadableFrames
                portReadableOctets
                portPygmys
                portRunts
                portFrameCheckSeqErrs
                portAlignmentErrors
                portFramesTooLong
                portAutoPartitionCount
            
            The address tracking group has a port table containing:
            
                portHubAddrID
                portGroupAddrID
                portAddrID
                portLastSourceAddress
                portSourceAddrChanges
            
            The bad bit clock group has a port table containing:

            
            
                                                               [Page   7]


            
                           XYPLEX IEEE ETHERNET HUB MIB      18 Oct 91
            
            
            
            
                portHubClockID
                portGroupClockID
                portClockID
                portOutOfSpecBitRate









































            
            
                                                               [Page   8]


            
                           XYPLEX IEEE ETHERNET HUB MIB      18 Oct 91
            
            
            
            6.  Definitions
            
                    XYPLEX-IEEE-HUB-MIB DEFINITIONS ::= BEGIN
            
                    IMPORTS
                            enterprises
                                    FROM RFC1155-SMI
                            DisplayString
                                    FROM RFC1158-MIB
                            OBJECT-TYPE
                                    FROM RFC1212-CONCISE-MIB;
            
            xyplex          OBJECT IDENTIFIER ::= { enterprises 33 }
            ieeeHub         OBJECT IDENTIFIER ::= { xyplex 10001 }
            
            -- From this point on, all object descriptors and
            -- identifiers are as specified in [11] except for the
            -- reduction of certain tables to become scalars
            
            hmBasicCapability        OBJECT IDENTIFIER ::= { ieeeHub 1 }
            hmSelfTestCapability     OBJECT IDENTIFIER ::= { ieeeHub 2 }
            hmPerfMonCapability      OBJECT IDENTIFIER ::= { ieeeHub 3 }
            hmAddrTrackCapability    OBJECT IDENTIFIER ::= { ieeeHub 4 }
            hmBadBitClockCapability  OBJECT IDENTIFIER ::= { ieeeHub 5 }
            
            --  This MIB module uses the extended OBJECT-TYPE macro as
            --  defined in [9]
            
            --  this is the IEEE 802 model MIB module for Xyplex
            --  Ethernet hubs
















            
            
                                                               [Page   9]


            
                           XYPLEX IEEE ETHERNET HUB MIB      18 Oct 91
            
            
            
            -- the IEEE 802 Hub group
            
            -- Implementation of this group is mandatory for all Xyplex
            -- Ethernet hubs
            
            -- the basic group
            
            -- IEEE 802 specifies a hub table, Xyplex does not
            
            hmBasicHubTable          OBJECT IDENTIFIER ::=
                                              { hmBasicCapability 1 }
            hmBasicHubEntry          OBJECT IDENTIFIER ::=
                                              { hmBasicHubTable 1 }
            hubID OBJECT-TYPE
                SYNTAX OCTET STRING (SIZE (6))
                ACCESS read-only
                STATUS mandatory
                DESCRIPTION
                    "The hub's Ethernet address."
                ::= { hmBasicHubEntry 1 }
            
            hubGroupCapacity OBJECT-TYPE
                SYNTAX INTEGER (1..255)
                ACCESS read-only
                STATUS mandatory
                DESCRIPTION
                    "The maximum number of groups the hub can have; a 
                    constant 1."
                ::= { hmBasicHubEntry 2 }
            
            hubGroupMap OBJECT-TYPE
                SYNTAX OCTET STRING (SIZE (32))
                ACCESS read-only
                STATUS mandatory
                DESCRIPTION
                    "A bit map of defined groups."
                ::= { hmBasicHubEntry 3 }
            
            -- IEEE 802 specifies a group table, Xyplex does not
            
            hmBasicGroupTable        OBJECT IDENTIFIER ::=
                                              { hmBasicCapability 2 }
            hmBasicGroupEntry        OBJECT IDENTIFIER ::=
                                              { hmBasicGroupTable 1 }
            
            groupHubID OBJECT-TYPE

            
            
                                                               [Page  10]


            
                           XYPLEX IEEE ETHERNET HUB MIB      18 Oct 91
            
            
            
                SYNTAX OCTET STRING (SIZE (6))
                ACCESS read-only
                STATUS mandatory
                DESCRIPTION
                    "The hub's Ethernet address."
                ::= { hmBasicGroupEntry 1 }
            
            groupID OBJECT-TYPE
                SYNTAX INTEGER (1..255)
                ACCESS read-only
                STATUS mandatory
                DESCRIPTION
                    "The identification number of the hub's only group; 
                    a constant 1."
                ::= { hmBasicGroupEntry 2 }
            
            groupNumberOfPorts OBJECT-TYPE
                SYNTAX INTEGER (1..255)
                ACCESS read-only
                STATUS mandatory
                DESCRIPTION
                    "The number of physical Ethernet ports on the hub."
                ::= { hmBasicGroupEntry 3 }























            
            
                                                               [Page  11]


            
                           XYPLEX IEEE ETHERNET HUB MIB      18 Oct 91
            
            
            
            -- the basic port table
            
            hmBasicPortTable OBJECT-TYPE
                SYNTAX SEQUENCE OF HmBasicPortEntry
                ACCESS not-accessible
                STATUS mandatory
                DESCRIPTION
                    "A list of basic hub Ethernet port entries."
                ::= { hmBasicCapability 3 }
            
            hmBasicPortEntry OBJECT-TYPE
                SYNTAX HmBasicPortEntry
                ACCESS not-accessible
                STATUS mandatory
                DESCRIPTION
                    "Parameter values for a port."
                INDEX { portHubBasicID }
                ::= { hmBasicPortTable 1 }
            
            HmBasicPortEntry ::=
                SEQUENCE {
                    portHubBasicID
                        OCTET STRING,
                    portGroupBasicID 
                        INTEGER,
                    portBasicID
                        INTEGER,
                    portType
                        INTEGER,
                    portAdminState
                        INTEGER,
                    portAutoPartitionState
                        INTEGER
                }
            
            portHubBasicID OBJECT-TYPE
                SYNTAX OCTET STRING (SIZE (6))
                ACCESS read-only
                STATUS mandatory
                DESCRIPTION
                    "The hub's Ethernet address."
                ::= { hmBasicPortEntry 1 }
            
            portGroupBasicID OBJECT-TYPE
                SYNTAX INTEGER (1..255)
                ACCESS read-only

            
            
                                                               [Page  12]


            
                           XYPLEX IEEE ETHERNET HUB MIB      18 Oct 91
            
            
            
                STATUS mandatory
                DESCRIPTION
                    "Group number; a constant 1."
                ::= { hmBasicPortEntry 2 }
            
            portBasicID OBJECT-TYPE
                SYNTAX INTEGER (1..255)
                ACCESS read-only
                STATUS mandatory
                DESCRIPTION
                    "A unique value for each Ethernet port.  Its value 
                    ranges between 1 and the value of 
                    groupNumberOfPorts.  The value for each port must 
                    remain constant at least from one re-initialization 
                    of the network management agent to the next."
                ::= { hmBasicPortEntry 3 }
            
            portType OBJECT-TYPE
                SYNTAX INTEGER { other(1), repeater(2),
                                  tenBASE-FAsync(3), tenBASE-FSynch(4) }
                ACCESS read-only
                STATUS mandatory
                DESCRIPTION
                    "The port type, with the following meanings:
            
                    other               not listed here
                    repeater            802.3 sec. 9 rptr port
                    tenBASE-FAsync(3)   async port on 10BASE-FA
                    tenBASE-FSynch(4)   sync port on 10BASE-FA
                    "
                ::= { hmBasicPortEntry 4 }
            
            portAdminState OBJECT-TYPE
                SYNTAX INTEGER { other(1), disabled(2), enabled(3) }
                ACCESS read-write
                STATUS mandatory
                DESCRIPTION
                    "Control over the port's ability to transmit and 
                    receive.  Corresponds directly to PORT 
                    ENABLED/DISABLED and the value labeled 'State:' in 
                    the PORT display."
                ::= { hmBasicPortEntry 5 }
            
            portAutoPartitionState OBJECT-TYPE
                SYNTAX INTEGER { other(1), notAutoPartitioned(2),
                                 autoPartitioned(3) }

            
            
                                                               [Page  13]


            
                           XYPLEX IEEE ETHERNET HUB MIB      18 Oct 91
            
            
            
                ACCESS read-only
                STATUS mandatory
                DESCRIPTION
                    "The port's status with regard to automatic 
                    partitioning.  Corresponds directly to the value 
                    labeled 'Auto Partitioned:' in the PORT display."
                ::= { hmBasicPortEntry 6 }







































            
            
                                                               [Page  14]


            
                           XYPLEX IEEE ETHERNET HUB MIB      18 Oct 91
            
            
            
            -- the self test group
            
            -- IEEE 802 specifies a table, Xyplex does not
            
            hmSelfTestHubTable       OBJECT IDENTIFIER ::=
                                              { hmSelfTestCapability 1 }
            hmSelfTestHubEntry       OBJECT IDENTIFIER ::=
                                              { hmSelfTestHubTable 1 }
            
            hubSelfTestID OBJECT-TYPE
                SYNTAX OCTET STRING (SIZE (6))
                ACCESS read-only
                STATUS mandatory
                DESCRIPTION
                    "The hub's Ethernet address."
                ::= { hmSelfTestHubEntry 1 }
            
            hubResetTimeStamp OBJECT-TYPE
                SYNTAX TimeTicks
                ACCESS read-only
                STATUS mandatory
                DESCRIPTION
                    "The value of sysUpTime when the hub was last 
                    reset."
                ::= { hmSelfTestHubEntry 2 }
            
            hubHealthState OBJECT-TYPE
                SYNTAX  INTEGER { other(1), ok(2), failed(3) }
                ACCESS read-only
                STATUS mandatory
                DESCRIPTION
                    "Indication of hub operational failure."
                ::= { hmSelfTestHubEntry 3 }
            
            hubHealthText OBJECT-TYPE
                SYNTAX DisplayString (SIZE (0..255))
                ACCESS read-only
                STATUS mandatory
                DESCRIPTION
                    "Free form text description of hub operational 
                    state."
                ::= { hmSelfTestHubEntry 4 }
            
            hubHealthData OBJECT-TYPE
                SYNTAX OCTET STRING (SIZE (0..255))
                ACCESS read-only

            
            
                                                               [Page  15]


            
                           XYPLEX IEEE ETHERNET HUB MIB      18 Oct 91
            
            
            
                STATUS mandatory
                DESCRIPTION
                    "Free form binary data description of hub 
                    operational state."
                ::= { hmSelfTestHubEntry 5 }
            
            hubSystemResetting OBJECT-TYPE
                SYNTAX INTEGER { notResetting(1), resetting(2) }
                ACCESS read-write
                STATUS mandatory
                DESCRIPTION
                    "Control to cause initialization of hub, reset of 
                    management counters, ad reset of hub parameters to 
                    defaults."
                ::= { hmSelfTestHubEntry 6 }
            
            hubResetting OBJECT-TYPE
                SYNTAX INTEGER { notResetting(1), resetting(2) }
                ACCESS read-write
                STATUS mandatory
                DESCRIPTION
                    "Control to cause initialization of the relay and 
                    port counters and flags related to the 
                    auto-partition function.  This does not affect hub 
                    management counters."
                ::= { hmSelfTestHubEntry 7 }
            
            hubExecutingSelfTest OBJECT-TYPE
                SYNTAX INTEGER { notSelfTesting(1), selfTesting(2) }
                ACCESS read-write
                STATUS mandatory
                DESCRIPTION
                    "Control to cause execution of a non-disruptive self 
                    test."
                ::= { hmSelfTestHubEntry 8 }











            
            
                                                               [Page  16]


            
                           XYPLEX IEEE ETHERNET HUB MIB      18 Oct 91
            
            
            
            -- the performance monitor group
            
            -- IEEE 802 specifies a table, Xyplex does not
            
            hmPerfMonRelayTable      OBJECT IDENTIFIER ::=
                                              { hmPerfMonCapability 1 }
            hmPerfMonRelayEntry      OBJECT IDENTIFIER ::=
                                              { hmPerfMonRelayTable 1 }
            relayHubPerfID OBJECT-TYPE
                SYNTAX OCTET STRING (SIZE (6))
                ACCESS read-only
                STATUS mandatory
                DESCRIPTION
                    "The hub's Ethernet address."
                ::= { hmPerfMonRelayEntry 1 }
            
            relayPerfID OBJECT-TYPE
                SYNTAX INTEGER (1..4)
                ACCESS read-only
                STATUS mandatory
                DESCRIPTION
                    "Relay identification; a constant 1."
                ::= { hmPerfMonRelayEntry 2 }
            
            relayTotalCollisions OBJECT-TYPE
                SYNTAX Counter
                ACCESS read-only
                STATUS mandatory
                DESCRIPTION
                    "The number of times the hub transmitted and 
                    simultaneously detected external activity on one or 
                    more ports."
                ::= { hmPerfMonRelayEntry 3 }













            
            
                                                               [Page  17]


            
                           XYPLEX IEEE ETHERNET HUB MIB      18 Oct 91
            
            
            
            -- the performance monitoring port table
            
            hmPerfMonPortTable OBJECT-TYPE
                SYNTAX SEQUENCE OF HmPerfMonPortEntry
                ACCESS not-accessible
                STATUS mandatory
                ::= { hmPerfMonCapability 2 }
            
            hmPerfMonPortEntry OBJECT-TYPE
                SYNTAX HmPerfMonPortEntry
                ACCESS not-accessible
                STATUS mandatory
                ::= { hmPerfMonPortTable 1 }
            
            HmPerfMonPortEntry ::=
                SEQUENCE {
                    portHubPerfID
                        OCTET STRING,
                    portGroupPerfID 
                        INTEGER,
                    portPerfID
                        INTEGER,
                    portReadableFrames
                        Counter,
                    portReadableOctets
                        Counter,
                    portPygmys
                        Counter,
                    portRunts
                        Counter,
                    portFrameCheckSeqErrs
                        Counter,
                    portAlignmentErrors
                        Counter,
                    portFramesTooLong
                        Counter,
                    portAutoPartitionCount
                        Counter
                }
            
            portHubPerfID OBJECT-TYPE
                SYNTAX OCTET STRING (SIZE (6))
                ACCESS read-only
                STATUS mandatory
                DESCRIPTION
                    "The hub's Ethernet address."

            
            
                                                               [Page  18]


            
                           XYPLEX IEEE ETHERNET HUB MIB      18 Oct 91
            
            
            
                ::= { hmPerfMonPortEntry 1 }
            
            portGroupPerfID OBJECT-TYPE
                SYNTAX INTEGER (1..255)
                ACCESS read-only
                STATUS mandatory
                DESCRIPTION
                    "The group number; a constant 1."
                ::= { hmPerfMonPortEntry 2 }
            
            portPerfID OBJECT-TYPE
                SYNTAX INTEGER (1..255)
                ACCESS read-only
                STATUS mandatory
                DESCRIPTION
                    "A unique value for each Ethernet port, identifying 
                    the same port as the equivalent value of 
                    portBasicID."
                ::= { hmPerfMonPortEntry 3 }
            
            portReadableFrames OBJECT-TYPE
                SYNTAX Counter
                ACCESS read-only
                STATUS mandatory
                DESCRIPTION
                    "Number of frames received with legal length and no 
                    corruption in transmission.  Corresponds directly 
                    with the value labeled 'Received Frames:' in the 
                    PORT display."
                ::= { hmPerfMonPortEntry 4 }
            
            portReadableOctets OBJECT-TYPE
                SYNTAX Counter
                ACCESS read-only
                STATUS mandatory
                DESCRIPTION
                    "The number of data and padding bytes represented by 
                    portReadableFrames."
                ::= { hmPerfMonPortEntry 5 }
            
            portPygmys OBJECT-TYPE
                SYNTAX Counter
                ACCESS read-only
                STATUS mandatory
                DESCRIPTION
                    "Number of message fragments less than 64 +/- 10 

            
            
                                                               [Page  19]


            
                           XYPLEX IEEE ETHERNET HUB MIB      18 Oct 91
            
            
            
                            bits long, possibly indicating external noise 
                    problems.  Corresponds directly with the value 
                    labeled 'Fragments (Pygmy):' in the PORT display."
                ::= { hmPerfMonPortEntry 6 }
            
            portRunts OBJECT-TYPE
                SYNTAX Counter
                ACCESS read-only
                STATUS mandatory
                DESCRIPTION
                    "Number of collision fragments longer than a pygmy 
                    but shorter than a legal message.  These occur as a 
                    result of normal collision operation.  Corresponds 
                    directly with the value labeled 'Short Frames 
                    (Runt):' in the PORT display."
                ::= { hmPerfMonPortEntry 7 }
            
            portFrameCheckSeqErrs OBJECT-TYPE
                SYNTAX Counter
                ACCESS read-only
                STATUS mandatory
                DESCRIPTION
                    "Number of frames received with integral bytes but 
                    invalid FCS.  Corresponds directly with the value 
                    labeled 'Check Sequenct (CRC):' in the PORT 
                    display."
                ::= { hmPerfMonPortEntry 8 }
            
            portAlignmentErrors OBJECT-TYPE
                SYNTAX Counter
                ACCESS read-only
                STATUS mandatory
                DESCRIPTION
                    "Number of frames received with an incomplete 
                    bytes."
                ::= { hmPerfMonPortEntry 9 }
            
            portFramesTooLong OBJECT-TYPE
                SYNTAX Counter
                ACCESS read-only
                STATUS mandatory
                DESCRIPTION
                    "Number of frames received of length greater than 
                    1518 bytes.  Corresponds directly with the value 
                    labeled 'Long Frames (>1518):' in the PORT 
                    display."

            
            
                                                               [Page  20]


            
                           XYPLEX IEEE ETHERNET HUB MIB      18 Oct 91
            
            
            
                ::= { hmPerfMonPortEntry 10 }
            
            portAutoPartitionCount OBJECT-TYPE
                SYNTAX Counter
                ACCESS read-only
                STATUS mandatory
                DESCRIPTION
                    "Number of times the repeater has automatically 
                    partitioned the port.  Corresponds directly with the 
                    value labeled 'Auto Partitions:' in the PORT 
                    display."
                ::= { hmPerfMonPortEntry 11 }


































            
            
                                                               [Page  21]


            
                           XYPLEX IEEE ETHERNET HUB MIB      18 Oct 91
            
            
            
            -- the address tracking port table
            
            hmAddrTrackPortTable OBJECT-TYPE
                SYNTAX SEQUENCE OF HmAddrTrackPortEntry
                ACCESS not-accessible
                STATUS mandatory
                ::= { hmAddrTrackCapability 1 }
            
            hmAddrTrackPortEntry OBJECT-TYPE
                SYNTAX HmAddrTrackPortEntry
                ACCESS not-accessible
                STATUS mandatory
                ::= { hmAddrTrackPortTable 1 }
            
            HmAddrTrackPortEntry ::=
                SEQUENCE {
                    portHubAddrID
                        OCTET STRING,
                    portGroupAddrID 
                        INTEGER,
                    portAddrID
                        INTEGER,
                    portLastSourceAddress
                        NetworkAddress,
                    portSourceAddrChanges
                        Counter
                }
            
            portHubAddrID OBJECT-TYPE
                SYNTAX OCTET STRING (SIZE (6))
                ACCESS read-only
                STATUS mandatory
                DESCRIPTION
                    "The hub's Ethernet address."
                ::= { hmAddrTrackPortEntry 1 }
            
            portGroupAddrID OBJECT-TYPE
                SYNTAX INTEGER (1..255)
                ACCESS read-only
                STATUS mandatory
                DESCRIPTION
                    "The group number; a constant 1."
                ::= { hmAddrTrackPortEntry 2 }
            
            portAddrID OBJECT-TYPE
                SYNTAX INTEGER (1..255)

            
            
                                                               [Page  22]


            
                           XYPLEX IEEE ETHERNET HUB MIB      18 Oct 91
            
            
            
                ACCESS read-only
                STATUS mandatory
                DESCRIPTION
                    "A unique value for each Ethernet port, identifying 
                    the same port as the equivalent value of 
                    portBasicID."
                ::= { hmAddrTrackPortEntry 3 }
            
            portLastSourceAddress OBJECT-TYPE
                SYNTAX OCTET STRING (SIZE (6))
                ACCESS read-only
                STATUS mandatory
                DESCRIPTION
                    "Source address of the last readable frame received 
                    on the port.  Corresponds directly with the value 
                    labeled 'Last Address:' in the PORT display."
                ::= { hmAddrTrackPortEntry 4 }
            
            portSourceAddrChanges OBJECT-TYPE
                SYNTAX Counter
                ACCESS read-only
                STATUS mandatory
                DESCRIPTION
                    "Number of times portLastSourceAddress has changed.  
                    Corresponds directly with the value labeled 'Address 
                    Changes:' in the PORT display."
                ::= { hmAddrTrackPortEntry 5 }



















            
            
                                                               [Page  23]


            
                           XYPLEX IEEE ETHERNET HUB MIB      18 Oct 91
            
            
            
            -- bad bit clock port table
            
            hmBadBitClockPortTable OBJECT-TYPE
                SYNTAX SEQUENCE OF HmBadBitClockPortEntry
                ACCESS not-accessible
                STATUS mandatory
                ::= { hmBadBitClockCapability 1 }
            
            hmBadBitClockPortEntry OBJECT-TYPE
                SYNTAX HmBadBitClockPortEntry
                ACCESS not-accessible
                STATUS mandatory
                ::= { hmBadBitClockPortTable 1 }
            
            HmBadBitClockPortEntry ::=
                SEQUENCE {
                    portHubClockID
                        OCTET STRING,
                    portGroupClockID 
                        INTEGER,
                    portClockID
                        INTEGER,
                    portOutOfSpecBitRate
                        Counter
                }
            
            portHubClockID OBJECT-TYPE
                SYNTAX OCTET STRING (SIZE (6))
                ACCESS read-only
                STATUS mandatory
                DESCRIPTION
                    "The hub's Ethernet address."
                ::= { hmBadBitClockPortEntry 1 }
            
            portGroupClockID OBJECT-TYPE
                SYNTAX INTEGER (1..255)
                ACCESS read-only
                STATUS mandatory
                DESCRIPTION
                    "The group number; a constant 1."
                ::= { hmBadBitClockPortEntry 2 }
            
            portClockID OBJECT-TYPE
                SYNTAX INTEGER (1..255)
                ACCESS read-only
                STATUS mandatory

            
            
                                                               [Page  24]


            
                           XYPLEX IEEE ETHERNET HUB MIB      18 Oct 91
            
            
            
                DESCRIPTION
                    "A unique value for each Ethernet port, identifying 
                    the same port as the equivalent value of 
                    portBasicID."
                ::= { hmBadBitClockPortEntry 3 }
            
            portOutOfSpecBitRate OBJECT-TYPE
                SYNTAX Counter
                ACCESS read-only
                STATUS mandatory
                DESCRIPTION
                    "Number of received frames with the transmission 
                    frequency detectably out of specification.  
                    Corresponds directly with the value labeled 'Out of 
                    Spec. Bit Rate:' in the PORT display."
                ::= { hmBadBitClockPortEntry 4 }
            
            END




























            
            
                                                               [Page  25]


            
                           XYPLEX IEEE ETHERNET HUB MIB      18 Oct 91
            
            
            
            7.  References
            
            [1]  V. Cerf, IAB Recommendations for the Development of 
            Internet Network Management Standards.  Internet Working 
            Group Request for Comments 1052.  Network Information 
            Center, SRI International, Menlo Park, California, (April, 
            1988).
            
            [2]  V. Cerf, Report of the Second Ad Hoc Network Management 
            Review Group, Internet Working Group Request for Comments 
            1109.  Network Information Center, SRI International, Menlo 
            Park, California, (August, 1989).
            
            [3]  M.T. Rose (editor), Management Information Base for 
            Network Management of TCP/IP-based internets, Internet 
            Working Group Request for Comments 1158.  Network 
            Information Center, SRI International, Menlo Park, 
            California, (May, 1990).
            
            [4]  M.T. Rose and K. McCloghrie, Structure and 
            Identification of Management Information for TCP/IP-based 
            internets, Internet Working Group Request for Comments 1155. 
            Network Information Center, SRI International, Menlo Park, 
            California, (May, 1990).
            
            [5]  K. McCloghrie and M.T. Rose, Management Information 
            Base for Network Management of TCP/IP-based 
            internets:MIB-II, Internet Working Group Request for 
            Comments 1213. Network Information Center, SRI 
            International, Menlo Park, California, (March 1991).
            
            [6]  J.D. Case, M.S. Fedor, M.L. Schoffstall, and J.R. 
            Davin, Simple Network Management Protocol, Internet Working 
            Group Request for Comments 1157.  Network Information 
            Center, SRI International, Menlo Park, California, (May, 
            1990).
            
            [7]  Information processing systems - Open Systems 
            Interconnection - Specification of Abstract Syntax Notation 
            One (ASN.1), International Organization for Standardization.  
            International Standard 8824, (December, 1987).
            
            [8]  Information processing systems - Open Systems 
            Interconnection - Specification of Basic Encoding Rules for 
            Abstract Notation One (ASN.1), International Organization 
            for Standardization.  International Standard 8825, 

            
            
                                                               [Page  26]


            
                           XYPLEX IEEE ETHERNET HUB MIB      18 Oct 91
            
            
            
            (December, 1987).
            
            [9] M.T. Rose, K. McCloghrie (editors), Towards Concise MIB 
            Definitions, Internet Working Group Request for Comments 
            1212. Network Information Center, SRI International, Menlo 
            Park, California, (March, 1991).
            
            [10] Definitions of Managed Objects for Xyplex Systems, 
            Xyplex document number 420-0545, (August, 1991).
            
            [11] Draft Supplement to ANSI/IEEE STD 802.3 - 1990 Edition, 
            CSMA/CD Access Method & Physical Layer Specifications, Layer 
            Management for Hub Devises, Section 18, draft of 5 
            September 1990.
            































            
            